ABB ACS350 MANUAL PDF

View and Download ABB ACS user manual online. ACS Inverter pdf manual download. Document library, contact your local ABB representative. FENA/ Ethernet adapter module user’s manual ACS, ACS and ACS ABB ACS Users Guide – Free ebook download as PDF File .pdf), Text File . txt) or read book ACS Drives 22 kW 30 HP User’s Manual.

Author: Nikorg Tygojas
Country: Bahrain
Language: English (Spanish)
Genre: Music
Published (Last): 15 August 2004
Pages: 247
PDF File Size: 15.41 Mb
ePub File Size: 5.24 Mb
ISBN: 989-6-51007-819-2
Downloads: 28385
Price: Free* [*Free Regsitration Required]
Uploader: Kagabar

ABB ACS USER MANUAL Pdf Download.

Power Cable Sizes And Fuses Power cable sizes and fuses Cable dimensioning for rated currents I is shown in the table below together with the corresponding fuse types acs305 short-circuit protection of the input power cable. Speed Control Fieldbus interface as the source for forcing ramp input to zero, i.

The update time for the frequency input is 50 ms. Reference Trimming Reference trimming In reference trimming, the external reference is corrected depending mamual the measured value mnaual a secondary application variable. Direction change is locked. The upper case boldface text refers to the states shown in the following block diagram ABB Drives profile Control Word parameter Make sure that dust from drilling does not enter the drive during the installation.

Selects the parity setting.

ABB ACS350 – 7.5kW 230V 3ph to 3ph – AC Inverter Drive Speed Controller

Page bit 0 Check motor power against unit power. The ACS works with either of two different control panel types: Modbus mapping The following modbus function codes are supported by the drive. A positive or zero minimum frequency value defines two ranges, one positive and one negative. Page 48 Enter the motor data from the motor nameplate: The control word is sent by the janual controller via the fieldbus adapter or embedded fieldbus modbus to the drive.

Drive control parameters After the fieldbus communication has been set up, the drive control acx350 listed in the table below should be checked and adjusted where necessary. Definition of motor set-up data. Read the safety instructions before you work on the drive.

  CIDCO ULWE MAP PDF

Page Fault tracing Falling edge of manial digital input DI1: Fieldbus adapter is connected to drive terminal X3.

In the following examples the reference is in mamual. Motor Ground the other end of the PE conductor at the distribution board. When frequency falls below the set level during run, the brake is closed.

ABB ACS350 User Manual

See chapter Technical data for the rated currents. Operation and start-up These warnings are intended for all who plan the operation, start up or operate the drive.

Contents Of The Assistant Displays Embedded fieldbus or an optional fieldbus adapter enables control over an open fieldbus link. To remove the battery, use a coin to rotate the battery holder on the back of the control panel. Pid Control Macro PID Control macro This macro provides parameter settings for closed-loop control systems such as pressure control, flow manial, etc.

Type Code You find the type code on the type designation label attached to the drive. Thermal overload protection of the motor According to regulations, the motor must be protected against thermal overload and the current must be switched off when overload is detected. The motor and control cables are selected as specified in this manual.

The communication profile on the fieldbus network depends on the type of the connected adapter. Replacement fans are available from ABB. See the figure below. Motor Cable Shield Motor cable shield To function as a protective conductor, the shield must have the same cross-sectional area as the phase conductors when they are made of the same metal.

Control panel Cleaning Use a soft damp cloth to clean the control panel. The following table includes the parameter default values for different macros. Mounting the drive Mount the drive Note: Make sure that the machinery into which the drive with brake control function is integrated fulfills the personnel safety regulations. Internal fault If the drive detects an internal fault, the drive is stopped and a fault indication is given.

  BLUE MOON LORI HANDELAND PDF

When both the reference DC Hold and the motor speed fall below the preset DC hold speed, the drive stops the motor and starts to inject DC DC hold speed into the motor. Unpacking the drive The drive 1 is delivered in a package that also contains the following items frame size R1 shown in the figure: With Pt the output current is 9.

Counts up Counter direction selection through digital input DI1. The longer the derivation time, the more the speed controller output is boosted during the change. The drive provides an underload function to protect the machinery and process in such a serious fault condition.

Do not use other than ABB specified spare parts. The installation must always be designed and made according to applicable local laws and regulations. Resistor Installation And Wiring Below is a simple wiring diagram example. Initially, the panel is in the Output mode, where you can Page 19 Product and service inquiries Address any inquiries about manua product to your local ABB representative, quoting the type code and serial number of the unit in question.

If sequence programming is deactivated by falling edge of digital input DI1, state machine is reset to state 1.

Configuration file reading error. Control Of A Mechanical Brake Control of a mechanical brake The mechanical brake is used for holding the motor and driven machinery at zero speed when the drive is stopped, or not powered.